Densonorm 21 ECO
Datasheet21 step sensitometer and densitometer with measuring arm integrated in one unit. For constancy testing of film processing and measurement of test phantom films.

21 step sensitometer and densitometer with measuring arm integrated in one unit. For constancy testing of film processing and measurement of test phantom films.

21 step sensitometer and densitometer with measuring arm integrated in one unit. For constancy testing of film processing and measurement of test phantom films.
Display of LE and LK after measurement of 21 step wedge densities and base+fog.
E-CAL: high precision sensitometer calibrated per DIN 6868/55. Suitable for use for acceptance testing.

21 step sensitometer and densitometer with measuring arm and scanner for motorized measurement of 21 step film strips in one unit.
Automatic calculation of speed index, contrast index (according to DIN or ANSI), LE, LK, rel. speed and aver. gradient. Memory function stores density values for up to 3 film strips. RS-232 interface for connection to a PC or compat. printer
i-CAL: high precision sensitometer calibrated per DIN 6868/55. Suitable for use for acceptance testing.
i-CAL-LAB: especially designed for professional laboratory use. Densitometer with highest precision and calibration of 10 points of the measurement range. Motorized measurement of 21-steps with density control.
Firmware for asymmetric film types (optional): for motorized measurement of 2 x 21 step wedges of asymmetrical film types followed by automatic calculation of LE and LK, speed index, contrast index (according to DIN or ANSI), rel. speed and aver. gradient.

Calibratable densitometer for single point measurements of optical densities of X-ray films.
i LE: with RS-232 interface. Can measure 21 step wedge densities and Dmin for automatic calculation of LE, LK, rel. speed and aver. gradient.
TR: especially for measurement of dry laser films (also usable for normal X-ray films).

Calibratable densitometer with measuring arm and scanner for motorized measurement of 21 step film strips.
Automatic calculation of speed index, contrast index (according to DIN or ANSI), LE, LK, rel. speed and aver. gradient.
Memory function stores density values for up to 3 film strips. RS-232 interface for connection to a PC or a compat. printer.
LAB: especially designed for professional laboratory use. Densitometer with highest precision and calibration of 10 points of the measurement range. Motorized measurement of 21-steps with density control.

21 step, dual-spectrum, single-side sensitometer for constancy testing of film processing of blue- and green-sensitive X-ray-films.
*CAL: high precision sensitometer calibrated per DIN 6868/55. Suitable for acceptance testing of film processing.
*Cine: especially designed for constancy testing of cine films.

Compact dual-spectrum, 5 point pocket sensitometer for constancy testing of dental films. Also usable for conventional blue- and green-sensitive X-ray films.

Pocket densitometer for single point measurements during quality control of dental films and conv. X-ray films.